Link (segment) Output Property Support
Output properties that can be activated for the output type: Link (segment).
Some output properties are not only contingent on the output type but on the combination of output type and PLANit traffic assignment component, such as, for example, the type of traffic assignment. For those specialised output properties, we direct the reader to the appropriate page of the PLANit component where these properties are listed.
We list the supported output properties for link (segment) ordered by their priority (id, input, output).
The Output property column lists the enum that is used to uniquely identify the property, whether it be in Java or Python.
ID_PRIORITY
Output Property | Description | Type | Unit |
---|---|---|---|
DOWNSTREAM_NODE_ID |
Link segment’s downstream node id (internal) | long | None |
DOWNSTREAM_NODE_XML_ID |
Link segment’s downstream node XML id (input) | string | None |
DOWNSTREAM_NODE_EXTERNAL_ID |
Link segment’s downstream node external id (input) | string | None |
ITERATION_INDEX |
Iteration index of simulation | integer | None |
LINK_SEGMENT_ID |
Link segment id (internal) | long | None |
LINK_SEGMENT_XML_ID |
Link segment XML id (input) | string | None |
LINK_SEGMENT_EXTERNAL_ID |
Link segment external id (input) | string | None |
LINK_SEGMENT_TYPE_ID |
Link segment type id (internal) | long | None |
LINK_SEGMENT_TYPE_NAME |
Link segment type name (input) | string | None |
LINK_SEGMENT_TYPE_XML_ID |
Link segment XML id (input) | string | None |
MODE_ID |
Mode id (internal) | long | None |
MODE_XML_ID |
Mode XML id (input) | string | None |
MODE_EXTERNAL_ID |
Mode external id (input) | string | None |
RUN_ID |
simulation run id | long | None |
TIME_PERIOD_ID |
time period id (internal) | long | None |
TIME_PERIOD_XML_ID |
time period XML id (input) | string | None |
TIME_PERIOD_EXTERNAL_ID |
time period external id (input) | string | None |
UPSTREAM_NODE_ID |
Link segment’s upstream node id (internal) | long | None |
UPSTREAM_NODE_XML_ID |
Link segment’s upstream XML node id (user) | string | None |
UPSTREAM_NODE_EXTERNAL_ID |
Link segment’s upstream external node id (user) | string | None |
INPUT_PRIORITY Fields
Output Property | Description | Type | Unit |
---|---|---|---|
CAPACITY_PER_LANE |
The capacity flow rate for a lane | float | pcu/h(/l) |
DOWNSTREAM_NODE_LOCATION |
The geographic location of the downstream node (if present) | string | SRS |
LENGTH |
The length | float | km |
LINK_TYPE |
The link segment type’s name (input) | string | None |
MAXIMUM_DENSITY |
The maximum density allowed on the link segment | float | pcu/km |
MAXIMUM_SPEED |
The maximum allowed speed | float | km/h |
NUMBER_OF_LANES |
The number of lanes | integer | None |
UPSTREAM_NODE_LOCATION |
The geographic location of the upstream node (if present) | string | SRS |
OUTPUT_PRIORITY Fields
Output Property | Description | Type | Unit |
---|---|---|---|
CALCULATED_SPEED |
The calculate speed | float | km/h |
COST_TIMES_FLOW |
The cost (per pcu) multiplied with the volume (per hour) on the entity | float | h (i.e., (h/pcu)*(pcu/1)) |
DENSITY |
The density on the link segment | float | pcu/km |
INFLOW |
The inflow rate | float | pcu/h |
FLOW |
The flow rate | float | pcu/h |
LINK_SEGMENT_COST |
The link segment’s generalised cost | float | h |
OUTFLOW |
The inflow rate | float | pcu/h |
VC_RATIO |
The volume to capacity ratio | float | None ((pcu/h)/(pcu/h) ) |